ContactRequest a DemoDemo Login

WPC-XML Module

The Redix WPC-XML Module is an optional add-on to the Redix AnyToAny or Network Server-Based Format Converter Engines and the XML module. The module contains 24 HIPAA XML maps. These maps convert HIPAA messages to XML messages followed WPC (Washington Publishing Corporation) Schema and vice versa.

WPC-XML module contains the following XML HIPAA maps. You can test the HIPAA and WPC-XML maps by going to Redix HIPAA Compliance and Conversion Demo.

Map NameSource Message TypeTarget Message Type
WPC_270_A1_to_HIPAA_A1

WPC XML 270

HIPAA 270 (4010A1)
WPC_271_A1_to_HIPAA_A1 WPC XML 271 HIPAA 271 (4010A1)
WPC_276_A1_to_HIPAA_A1 WPC XML 276 HIPAA 276 (4010A1)
WPC_277_A1_to_HIPAA_A1 WPC XML 277 HIPAA 277 (4010A1)
WPC_278_A1_to_HIPAA_A1 WPC XML 278 Request HIPAA 278 Request (4010A1)
WPC_278_A3_to_HIPAA_A1 WPC XML 278 Response HIPAA 278 Response (4010A1)
WPC_820_A1_to_HIPAA_A1 WPC XML 820 HIPAA 820 (4010A1)
WPC_834_A1_to_HIPAA_A1 WPC XML 834 HIPAA 834 (4010A1)
WPC_835_W1_to_HIPAA_A1 WPC XML 835 HIPAA 835 (4010A1)
WPC_837_Q1_PRO_to_HIPAA_A1 WPC XML 837 Professional HIPAA 837 Professional (4010A1)
WPC_837_Q2_DEN_to_HIPAA_A1 WPC XML 837 Dental HIPAA 837 Dental (4010A1)
WPC_837_Q3_INS_to_HIPAA_A1 WPC XML 837 Institutional HIPAA 837 Institutional (4010A1)
HIPAA_A1_270_to_WPC_270_A1-HAND HIPAA 270 (4010A1) WPC XML 270
HIPAA_A1_271_to_WPC_271_A1-HAND HIPAA 271 (4010A1) WPC XML 271
HIPAA_A1_276_to_WPC_276_A1-HAND HIPAA 276 (4010A1) WPC XML 276
HIPAA_A1_277_to_WPC_277_A1-HAND HIPAA 277 (4010A1) WPC XML 277
HIPAA_A1_278_REQ_to_WPC_278_A1-HAND HIPAA 278 Request (4010A1) WPC XML 278 Request
HIPAA_A1_278_RES_to_WPC_278_A3-HAND HIPAA 278 Response (4010A1) WPC XML 278 Response
HIPAA_A1_820_to_WPC_820_A1-HAND HIPAA 820 (4010A1) WPC XML 820
HIPAA_A1_834_to_WPC_834_A1-HAND HIPAA 834 (4010A1) WPC XML 834
HIPAA_A1_835_to_WPC_835_W1-HAND HIPAA 835 (4010A1) WPC XML 835
HIPAA_A1_837D_to_WPC_837_Q2_DEN-HAND HIPAA 837 Dental (4010A1) WPC XML 837 Dental
HIPAA_A1_837I_to_WPC_837_Q3_INS-HAND HIPAA 837 Institutional (4010A1) WPC XML 837 Institutional
HIPAA_A1_837P_to_WPC_837_Q1-HAND HIPAA 837 Professional (4010A1) WPC XML 837 Professional

 

 

  • Windows Server 2003 / Vista / 7 / Server 2008 / 8 / Server 2012 / 10 / Server 2016
  • UNIX (AIX 5.1+, Solaris 8/9/10, HP-UX 10+)
  • Linux (Red Hat, SUSE, etc.)
  • XML HIPAA

Corporate Headquarter

265 Davidson Avenue
Suite 142
Somerset, NJ 08873

Sales

888.850.8088
Sales Office available M-F 8:00 - 5:00 US Pacific Time
sales@redix.com

Support

888.850.8088
support@redix.com